• English
  • Hindi
  • Punjabi
  • Marathi
  • German
  • Gujarati
  • Urdu
  • Telugu
  • Bengali
  • Kannada
  • Odia
  • Assamese
  • Nepali
  • Spanish
  • French
  • Japanese
  • Arabic
  • Home
  • Noida
  • National
    • BulletsIn
    • cliQ Explainer
    • Government Policy
    • New India
  • International
    • Middle East
    • Foreign
  • Entertainment
  • Business
    • Tender News
  • Sports
    • IPL2025
  • Services
    • Lifestyle
    • How To
    • Spiritual
      • Festival and Culture
    • Tech
Notification
  • Home
  • Noida
  • National
    • BulletsIn
    • cliQ Explainer
    • Government Policy
    • New India
  • International
    • Middle East
    • Foreign
  • Entertainment
  • Business
    • Tender News
  • Sports
    • IPL2025
  • Services
    • Lifestyle
    • How To
    • Spiritual
      • Festival and Culture
    • Tech
  • Home
  • Noida
  • National
    • BulletsIn
    • cliQ Explainer
    • Government Policy
    • New India
  • International
    • Middle East
    • Foreign
  • Entertainment
  • Business
    • Tender News
  • Sports
    • IPL2025
  • Services
    • Lifestyle
    • How To
    • Spiritual
      • Festival and Culture
    • Tech
  • Noida
  • National
  • International
  • Entertainment
  • Business
  • Sports
CliQ INDIA > International > Foreign > Augmented reality guidance for placing intracranial drains now clinically validated
ForeignInternational

Augmented reality guidance for placing intracranial drains now clinically validated

cliQ India
cliQ India
Share
8 Min Read
SHARE

March 20, 2025 — Placing an external ventricular drain (EVD) at bedside using augmented reality (AR) guidance is more precise than freehand placement and is associated with fewer reinterventions and complications, according to a clinical pilot study of a novel system. Frederick Van Gestel, MD, a neurosurgery resident at Universitair Ziekenhuis Brussel and PhD researcher at Vrije Universiteit Brussel in Brussels, Belgium, and colleagues report first-in-human results in Neurosurgery, the official publication of the Congress of Neurological Surgeons. The journal is published in the Lippincott portfolio by Wolters Kluwer.

Conventional neuronavigation systems are restricted to the operating room because of their size and lack of mobility, the authors note. “Moreover, these systems necessitate unintuitive mental transformations of 2D information on remote displays into 3D action at the patient, dividing attention between both.” In contrast, “AR provides overlays of 3D information onto the real world and has the potential to augment the surgeon’s view with relevant data.”

Headset-based AR navigation system designed specifically for EVD placement

The new system pairs a commercial AR headset, in this case the Microsoft HoloLens II, with a surgical navigation software that was custom-built by the researchers. Their solution integrates all components necessary for neuronavigation (i.e. high-accuracy tracking, image display and processing unit) in a standalone headset, without requiring external cameras or computers. The first step in its use is preoperative imaging and creation of a 3D model of the patient’s anatomy, which is labeled with coordinates relevant for AR guidance, including the foramen of Monro as a target point. An infrared-labeled reference frame is attached to the patient’s head with a clamping headband, allowing the AR application to track head position and orientation.

The 3D model is exported to the AR headset into the surgical navigation application, and image-to-patient registration is achieved using an infrared-tracked stylus to match the virtual representation of the patient’s anatomy to the physical one. During EVD trajectory planning, the system determines the path to the foramen of Monro with the shortest distance between the skin surface and the ipsilateral frontal horn of the lateral ventricles to ensure the shortest path through brain parenchyma. The surgeon can adapt this trajectory on the fly by moving the stylus freely around the expected entry point, taking into account underlying anatomy or pathology, before confirming the patient-specific approach.

The trajectory and all necessary anatomical information are displayed as a 3D object on the patient and can be inspected from all angles, providing a sense of depth. A tracker is attached to the surgical drill, and the system indicates the translational and angular error of the drill bit’s tip and drilling direction based on the planned trajectory. Once these errors are reduced below predefined thresholds of 2 mm and 2°, the trajectory line turns green to indicate proper drill alignment. During drilling, this color-coded guidance continues to give feedback about alignment of the drill’s trajectory.

Pilot study: Complete absence of poor or failed placements

Following successful phantom studies, Dr. Van Gestel and three other neurosurgeons used the AR navigation system for intraoperative guidance during 11 EVD placement cases in a critical care setting, for adults presenting at their university hospital and requiring bedside EVD placement as their sole primary intervention. They also collected data on 11 patients who had an EVD placed at bedside using the freehand technique during the same timeframe, performed by one of the surgeons participating in the study.

AR guidance resulted in better placement outcomes and functional placement in all cases versus seven in the freehand group (statistically significant difference), successful in nine versus five, optimal in eight (including two slit ventricle cases) versus three (statistically significant difference), and failed in zero versus one. No AR-guided placement required revision, but four freehand placements did, another statistically significant difference.

“The reinterventions, along with the implied multitude of attempts, constituted the primary cause of all procedure-related complications in the freehand group,” the authors report, “once more emphasizing the hazard related to multiple stick-and-poke attempts and the importance of first-attempt success.”

“Although for some cases freehand placement might have been equally successful, the distinct improvement over the control group indicates that the freehand technique may not consistently yield straightforward results,” Dr. Van Gestel and his colleagues emphasize. “The performance in slit ventricle cases further substantiates these presumptions because accomplishing successful ventricular puncture can be notably challenging, especially within a single attempt.” Building on their initial success, the researchers are planning a multicenter randomized controlled trial, which is scheduled for launch at the end of 2025.

Read Article: High-Accuracy Augmented Reality Guidance for Intracranial Drain Placement Using a Standalone Head-Worn Navigation System: First-in-Human Results

Wolters Kluwer provides trusted clinical technology and evidence-based solutions that engage clinicians, patients, researchers, and students in effective decision-making and outcomes across healthcare. We support clinical effectiveness, learning and research, clinical surveillance and compliance, as well as data solutions. For more information about our solutions, visit https://www.wolterskluwer.com/en/health.

###

About Wolters Kluwer

Wolters Kluwer (EURONEXT: WKL) is a global leader in information, software solutions and services for professionals in healthcare; tax and accounting; financial and corporate compliance; legal and regulatory; corporate performance and ESG. We help our customers make critical decisions every day by providing expert solutions that combine deep domain knowledge with technology and services.

Wolters Kluwer reported 2024 annual revenues of €5.9 billion. The group serves customers in over 180 countries, maintains operations in over 40 countries, and employs approximately 21,400 people worldwide. The company is headquartered in Alphen aan den Rijn, the Netherlands.

For more information, visit www.wolterskluwer.com, follow us on LinkedIn, Facebook, YouTube and Instagram.


https%3A%2F%2Fwww.newswise.com%2Farticles%2Faugmented-reality-guidance-for-placing-intracranial-drains-now-clinically-validated%2F%3Fsc%3Drsla

You Might Also Like

Meet the University of Maryland School of Medicine Board of Visitors
Afghan women deserve their day in court against Taliban, ICJ could play important role: Human Rights group
Pak company announces gas load shedding for Ramadan
Families of abducted Baloch individuals block major roads at Khuzdar
UNESCO Honors Ramcharitmanas and Panchatantra for Global Literary Impact | BulletsIn

Sign Up For Daily Newsletter

Be keep up! Get the latest breaking news delivered straight to your inbox.
By signing up, you agree to our Terms of Use and acknowledge the data practices in our Privacy Policy. You may unsubscribe at any time.
Share This Article
Facebook Whatsapp Whatsapp Telegram Copy Link Print
Share
What do you think?
Love0
Sad0
Happy0
Angry0
Wink0
Previous Article Today’s Horoscope (21 March 2025)
Next Article Pakistan formally accepts Agreement on Fisheries Subsidies

Stay Connected

FacebookLike
XFollow
InstagramFollow
YoutubeSubscribe
TelegramFollow
- Advertisement -
Ad imageAd image

Latest News

Bengal Falta Repoll 2026: Massive Security Deployment After Election Controversy | Cliq Latest
National
May 21, 2026
Peddi Promotion Event In Bhopal: Ram Charan And AR Rahman Ready For Mega Show | Cliq Latest
Entertainment
May 21, 2026
Junior NTR Dragon Teaser Out: NTR Stuns Fans With Intense Assassin Avatar | Cliq Latest
Entertainment
May 21, 2026
KKR Vs MI IPL 2026: Manish Pandey And Bowlers Revive Kolkata Playoff Dream | Cliq Latest
Sports
May 21, 2026

//

We are rapidly growing digital news startup that is dedicated to providing reliable, unbiased, and real-time news to our audience.

We are rapidly growing digital news startup that is dedicated to providing reliable, unbiased, and real-time news to our audience.

Sign Up for Our Newsletter

Sign Up for Our Newsletter

Subscribe to our newsletter to get our newest articles instantly!

Follow US

Follow US

© 2026 cliQ India. All Rights Reserved.

CliQ INDIA
  • English – अंग्रेज़ी
  • Hindi – हिंदी
  • Punjabi – ਪੰਜਾਬੀ
  • Marathi – मराठी
  • German – Deutsch
  • Gujarati – ગુજરાતી
  • Urdu – اردو
  • Telugu – తెలుగు
  • Bengali – বাংলা
  • Kannada – ಕನ್ನಡ
  • Odia – ଓଡିଆ
  • Assamese – অসমীয়া
  • Nepali – नेपाली
  • Spanish – Española
  • French – Français
  • Japanese – フランス語
  • Arabic – فرنسي
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?